Nashik

'level control application'

Items tagged with 'level control application'

product image
Level Instruments - Mechanical Level Gauges.

Float & Board Level Indicators for Pressurized Tanks are designed for an accurate, reliable & trouble free float operated technique used in large tanks where there is blanketing system or, there are fumes / vapours in the tank by which tank gets pressurized. Range : 2 meters up to 6 meters Gauge Board : Follower Magnet type Indicator in provided in a transparent vertical tube. Float wire : 2mm dia.x SS 304 /SS 316 (multistrand) / 6mm dia. x PP (multistrand) Guide Wires : 2mm dia.x SS 304 /SS 316 (multistrand) / 6mm dia. x PP (multistrand) Float : SS 316, 300 mm dia X 75 mm height. Sheave assembly : Aluminum Housing, 2 nos. SS pulleys with Teflon bushes Indicator assembly : MS Painted Brackets for scale and indicator: MS Powder coated Nuts & Bolts : Zink plated MS Optional : Externally settable Switches for Control system or, feed backs.

Send Message
product image
Differential Pressure Instruments

DP Switches with Adjustable On-Off Differential Diaphragm type DP Switches with Adjustable On-Off Differential facility are used normally for automatic filter cleaning system or, for Level Control application in pressurized tanks. Various ranges and options for their selection are available. DP Ranges : varies from 0 to 150 mm Wc up to 0 to 7 bar Differential : Field Adjustable Accuracy : +/- 1% FS Migration : Impossible No. of Switches : One or, Two nos. Type of Switches : Micro Switches - SPDT, 5 A 250 V AC Enclosure class : IP 54, IP 65, IP 66 or, Flameproof Pressure Housing : MS or, SS Sensing Diaphragm : Neoprene, Teflon Process Connection : ¼” BSP-F (Standard) Temperature Range : -10 to 80 Degree C (for high-temperature use of impulse tube is advisable)

Send Message
product image
Differential Pressure Instruments

DP Switches with Fixed On-Off Differential We have Diaphragm type Differential Pressure Switches. These gauges are more in demand for DP control applications in HVAC / across Heat Exchangers / across Pumps / across Filters / across Strainers, Level Control applications in pressurized tanks, Ranges : from 0 to 150 mm WC up to 0 to 7 bar Differential : Fixed Accuracy : +/- 1% FS Temperature Range : -10 to 80 Degree C (for high-temperature use of impulse tube is advisable) Migration : Impossible No. of Switches : One or, Two. Type of Switches : Micro Switches - SPDT, 5 A 250 V AC Enclosure class : IP 54, IP 65, IP 66 or, Flameproof Pressure Housing : MS or, SS Sensing Diaphragm : Neoprene or, Teflon Process Connection : ¼” BSP-F (Standard)

Send Message

Still searching for
level control application?