product image
Differential Pressure Instruments

DP Switches with Adjustable On-Off Differential Diaphragm type DP Switches with Adjustable On-Off Differential facility are used normally for automatic filter cleaning system or, for Level Control application in pressurized tanks. Various ranges and options for their selection are available. DP Ranges : varies from 0 to 150 mm Wc up to 0 to 7 bar Differential : Field Adjustable Accuracy : +/- 1% FS Migration : Impossible No. of Switches : One or, Two nos. Type of Switches : Micro Switches - SPDT, 5 A 250 V AC Enclosure class : IP 54, IP 65, IP 66 or, Flameproof Pressure Housing : MS or, SS Sensing Diaphragm : Neoprene, Teflon Process Connection : ¼” BSP-F (Standard) Temperature Range : -10 to 80 Degree C (for high-temperature use of impulse tube is advisable)

Send Message
product image
Differential Pressure Instruments

DP Switches with Fixed On-Off Differential We have Diaphragm type Differential Pressure Switches. These gauges are more in demand for DP control applications in HVAC / across Heat Exchangers / across Pumps / across Filters / across Strainers, Level Control applications in pressurized tanks, Ranges : from 0 to 150 mm WC up to 0 to 7 bar Differential : Fixed Accuracy : +/- 1% FS Temperature Range : -10 to 80 Degree C (for high-temperature use of impulse tube is advisable) Migration : Impossible No. of Switches : One or, Two. Type of Switches : Micro Switches - SPDT, 5 A 250 V AC Enclosure class : IP 54, IP 65, IP 66 or, Flameproof Pressure Housing : MS or, SS Sensing Diaphragm : Neoprene or, Teflon Process Connection : ¼” BSP-F (Standard)

Send Message
product image
Vacuum Instruments-Vacuum Switches

We have Vacuum Sensors and Switches for Indication & Control applications. Vacuum Switches & Compound Range Switches are normally used in Vacuum Pumps or, Vacuum based systems where you have to ensure availability of Vacuum within Low & High set limits. So using Vacuum Switches you can control your process in On-Off mode. Vacuum Transmitters are used to know actual availability of Vacuum in the process and the same can be used to read or, control in proportionate or, On-Off mode. Flameproof Vacuum Switch is designed as per IS2148 for Gas Gr. IIC Flameproof - CE Certification and approved by a leading European Lab – “BASEEFA” for ATEX & ICEEX certificates Adjustable Range : 760 to 100 mm Hg Vacuum Diaphragm : Teflon or, Neoprene Pressure Housing MOC : Aluminium, Brass or, SS 316

Send Message
product image
Conductivity Instruments.

We manufacture OnLine Digital Conductivity Indicators and Conductivity Conrtrollers also. We have Temperature Compensdated type and Without Temperature Comprensated type Online Digital Conductivity Controllers. This Controller is provided along with the ONline Conductivity Electrode. The Digital Unit can be Field MOunted (Integral) or, Panel Mounted (Panel mounted) versions.. We offersSingle Relay or, 2 Delays in Conductivity Controllers. With these Relays the Conductivity of the flowing liquid can be controlled within the resired set limits.

Send Message
product image
Conductivity Instruments

We manufacture OnLine Digital Conductivity Indicators and Conductivity Conrtrollers also. We have Temperature Compensdated type and Without Temperature Comprensated type Online Digital Conductivity Controllers. This Controller is provided along with the ONline Conductivity Electrode. The Digital Unit can be Field MOunted (Integral) or, Panel Mounted (Panel mounted) versions.. We offersSingle Relay or, 2 Delays in Conductivity Controllers. With these Relays the Conductivity of the flowing liquid can be controlled within the resired set limits.

Send Message